Our Products
Physiotherapy Equipment
1 Products availableElectronic Components
1 Products availableEEG Machine
1 Products availableUsed Machinery & Tools
1 Products availableLeading Manufacturer, Supplier & Retailer of Electroencephalogram System, Electromyogram System, NBETTER Stroke Rehabilitation System, Wireless Bluetooth EEG and Portable Wifi EEG.
NS-EEG-D1 is a digital EEG device available in 24/36/48/60 channels. It delivers high quality EEG signals through state-of-the-art hardware and software design, built-in impedance test module and anti-interference data transmission technology. This device can be used for routine EEG, Event-Related Potential (ERP) data acquisition and analysis, as well as professional Sleep monitoring using Polysomnography (PSG) for medical and research institutions. System Key Features High quality signal with optical fiber isolation DC battery power operation eliminates AC power line interference Built-in impedance testing function Built-in impedance testing function Ergonomically designed single shielded cup/clip electrodes with touch-proof connectors (1.5mm) Choice of different configurations - 24/36/48/60 channels unipolar EEG 12 channels bipolar EEG Synchronous acquisition, editing and display of EEG and video signals Synchronised EEG examination and PSG recording enable for more sophisticated clinical applications
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Technical Specifications
Dimensions & Weights | |
---|---|
size | 290 x 245 X 65 mm |
Amplifier Weight | 2 Kg (approx) |
Power Supply | |
Power | DC 19V |
Operation Time | |
Duration | Up to 72 hours continuously |
Performance | |
Input Impedance | ≥1000MΩ |
Noise level | <0.4μV (rms) |
CMRR | ≥110dB |
Resistance polarization voltage | ± 300mV |
Frequency characteristics | 0.5Hz ~ 10KHz, error of +5% ~ -30% |
Impedance Test | Includes scalp impedance test function: Impedance lights on top of EEG amplifier can be set at 5KΩ, 10KΩ, 15KΩ or 20KΩ threshold values to indicate impedance status of each channel (red or yellow light indicates high impedance; green light means impedance is acceptably low) |
Channel Configuration | 24/36/48/60 channel EEG, where 12 of the EEG channels can be set as bipolar EEG; Additional channels for multi-parameters: 3 EMG, 1 ECG, 2 EOG, 1 abdominal breathing (RESP), 1 snoring, 1 nose and mouth airflow (Flow), 1 for SpO2 |
Sampling Frequency | 128Hz, 256Hz, 512Hz |
Interface Technology | USB 2.0 interface, transmission rate 480Mb (/12Mb)/s |
Fiber optic modules | Work rate ≤84Mb/s |
Precision sampling resolution | 24bit |
Low-pass filter | 15Hz, 30Hz, 40Hz, 60Hz, 120Hz, 250Hz, 1KHz, 3KHz |
Time constant | 0.01s, 0.02s, 0.03s, 0.1s, 0.2s, 0.3s, 1s, 2s, 3s |
Amplification | 1 – 10,000 times |
NS-EMG-C-1 is a digital EMG device. It acquires, stores and review up to 4 channels of EMG data and 2 channels evoked potential (EP) channels. It can perform routine EMG recording, EP, as well as nerve conductive velocity (NCV) diagnostic examination.
Operation Menu :
Guide for Electrode Placement : Easy-to-understand illustration for electrode placement, stimulation position and standard waveform
Case Management Module :
Examination Protocol: EMG :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Neurostyle Brain Exercise Therapy Towards Enhanced Recovery (nBETTER) is a rehabilitation system that detects visualized movements of stroke-affected limbs using Electroencephalography (EEG) based Neuro-feedback to provide visually engaging and mechanical feedback for exercising the brain towards better post-stroke recovery The first Brain Computer Interface (BCI) based Stroke Rehabilitation System in the market With new stroke rehab: Build new motor control pathway in the brain directly. Better can be used as a standalone application or deployed as an intranet or internet application (by putting some modules on the server). The subject’s information, performance parameters and recorded EEG signals are used to give input for neurofeedback.
System Key Features :
System Components :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
20 channel ambulatory eeg wireless bluetooth channel: 19 ch eeg + 1 ch ecg; 1. Event button to mark patient's epilepsy seizure; 2. Plug and play single electrode (din interface). Supports 19 eeg channels plus 1 channel ecg to meet with doctor's clinical requirements; low power consumption, capable of supporting up to 72 hours recording with 4 aa batteries; use of dc power supply eliminates risk of electric shock to patients and prevents signal interference, and removes the need to use ground wire or other shielding features; supports real-time eeg waveform recording and display via wireless bluetooth transmission, or dynamic recording with flash memory card capable of storing up to 2gb of eeg data (data storage capability depends fully on memory card used); fast data uploading capability: data stored in flash memory card via dynamic recording can be quickly transmitted to desktop or laptop computer through usb 2.0usb1.1 interface; single electrodes with touch proof connectors that meets international standard, and can be replaced individually if necessary; event button on the amplifier enables on-the-spot manual event marking of patient's epilepsy seizure during recording; compact design and easy to carry, complete with eeg signal isolation to support maximum patient movement without distortion; optional video system for recording, editing and displaying video images synchronously with eeg signals. Package: 1 carton delivery time: 3-5 days after payment confirmed
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
main features of 7128w-d36-ep 36 channel eegpsgerprnprofessional eeg amplifier suitable for all standard applications of routine eeg and long term eeg monitoring in the research and clinical areas.configurable in a number of setups according to users needsrn24 channels monopolar eeg;rn12 channels monopolar eeg + 12 channels bipolar eeg;rn24 channels monopolar eeg + 12 channels polysomnography (psg) parameters (including ecg (1 channel with 2 leads), airflow (1 channel), eog (2 channels), emg (3 channels), snore (1 channel), spo2 (1 channel), thoracic abdominal breathing (2 channels), body position (1 channel)) + erp examination.24 bits ad conversion rate, with high sampling rate of up to 8 khz.high quality real-time eeg signal acquisition is transmitted via fiber optical isolation, which shields away interference from power line and other signals, transmitting stable and reliable measurement data at high-speed while greatly ensuring patients safety.amplifier can be operated either by dc power without affecting signal quality.head-box design to access single shielded cupclip electrodes with touch proof connectors (1.5mm).built-in impedance testing function and automatic calibration (for both sine wave and square wave signals).optional video system for recording, editing and displaying video images synchronously with eeg signals. Delivery time 3-5 days after payment confirmed package 1 carton
This is a professional digital eeg device designed and developed to allow cliniciansrnto perform all standard applications of routine eeg and long term eeg monitoring anywhere due to its portable and compact design. rnit also has low power consumption making it capable of supporting up to 72 hours recording with just four aa batteries. rnthis device supports real-time eeg waveform recording and display via wi-fi and dynamic recording with flash memory card. Rnkey featurern rn1.compact design portable and easy to carry. rn2.complete with eeg isolation support maximum patient movement without distortion. rn3.user-friendly operation. rn4.low power consumption capable of supporting up to 72 hours recording with fourrnaa rnbatteries. rn5.supports real-time eeg waveform recording, display via wi-fi. rn6.dynamic recording with flash memory card. rn7.all-in-one electrode cable for easy connection. rn8.use of dc power supply: eliminates risk of electric shock to patientsrn prevents signal interferencern removes the need to use ground wire or other shielding featuresrn rn9.fast data uploading capability stored data in flash memory card can be quickly transferred to the computer through usb2.0/usb 1.1 interface. rn10.optional video system recording, editing and displaying of video synchronously with eeg signals.
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
amplifier:rninput channelsrn2/4; dual-fiber signal transmission isolationrnsensitivityrn0.05v/div -20 mv/divrnamplitude-frequency characteristicrn1hz5khzrnnoisern0.4v (vp-p)rnimpedancern>1000mrncmrrrn110dbrngain amplifierrn50 times 50 million timesrnmax higher filters frequencyrn50hzrnmin lower filters frequencyrn0.1hzcontroller (included in the main unit):rna/d conversion rate 24bitrnsample rate 200 khzrnstimulus frequency 0.1 - 50 hzrnanalysis time 1 - 1000msrnsplice time 1-5000 timescurrent stimulator (included in the main unit)rncurrent intensity output range: 0 100ma, error 10%rnstimulus modes: single-current stimulator, dual-current stimulatorrnstimulus frequency: 0.1 hz 100hz, error 10%rnstimulus width: 501000srnpulse duration error: 0.05ms, 0.1ms, 0.5ms, 1ms, error 10%rnpulse mode: single pulse, double pulse, three pulses.A/v stimulatorrnsound (configured with headphone)rnstimulus intensity: 30120 dbrnstimulus frequency: 0.120hrnstimulation method: rare wave, dense wave, alternative wavern rnpictures (configured with pattern reversal stimulator)rna) pattern mode: checkerboard, vertical grid, bar gridrnb) image size: 64*32, 32*24, 16*12, 8*6, 4*4.c) vision: full vision, half-field (left), 1 / 4 view (i, ii, iii, iv quadrant)rnd) stimulation frequency: 1 20 times / secrne) free to edit, set the pattern or color pattern.rnflash (configured with goggles)rnstimulus frequency: 0.1 20hz adjustablern rnportable suitcase (aluminum)rndirnmension& weight: 430*380*150(mm); 4.02kg
specification of nts-2000 2/4 channels emgrnamplifierrnchannels:rn2 /4 channel, dual-fiber signal transmission isolationrnsensitivity:rn0.05v/div - 20 mv/divrnamplitude-frequency characteristic: rn1hz5khzrnnoise: 0.4v (vp-p)rnimpedance :>1000mrncmrr: 110dbrngain amplifier: rn50 times 50 million timesrnmax higher filters frequency:rn50hzrnmin lower filters frequency:rn0.1hzrncontroller (included in operation panel)rna/d conversion rate:rn24bitrnsample rate:rn200 khzrnstimulus frequency:rn0.1-50 hzrnanalysis time: rn1 - 1000msrnsplice time:rn1 5000 timesrncurrent stimulatorrncurrent intensity output range:rn0 100ma, error 10%rnstimulus modes:rnsingle-current stimulator, dual-current stimulatorrnstimulus frequency:rn0.1 hz 100hz, error 10%rnstimulus width:rn501000srnpulse duration error:rn0.05ms, 0.1ms, 0.5ms, 1ms, error 10%rnpulse mode:rnsingle pulse, double pulse, three pulses.
.featuresrn1. Multi-channel acquisition: optional 8 and 16 channels with high anti-interference capacity; rn2. Real-time wireless data transmission, dynamic data storage suitable for signal acquisition in movement state; rn3. Multiple data processing and analysis reports: standard, fatigue, coordination, average activity, power spectrum, symmetry etc., exportable for further analysis; rn4. Multi-media biofeedback games make training more efficient and no longer boring. Rn5. Non-invasive: no need to insert needle into the detected muscle, and just stick electrodes on the surface of detected musclern rn6. Multiple quantitative assessment: occurrence period, amplitude, rms value and frequency of emg activity potential and all kinds of analysis reports. Rn7. Program modules function: 6 types semg test and reports for different situation, funny semg biofeedback game training; rn8. Human-friendly software: acquisition, display, analysis and reports generating. Rnapplicationsrnthis equipment can be widely used in hospitals, sports science and lab research. 1. Hemiplegia assessment after cerebral palsy and stroke (neurology, rehabilitation department)rn2. Pain assessment, balance function evaluation, neuromuscular disease diagnosisrn3. Scoliosis, torticollis generic program (pediatrics, rehabilitation department):rn4. Feedback muscle training, muscle function/movement evaluation (rehabilitation department):rn5. Fatigue research (rehabilitation department, sports schools, and athletic teams);rn6. Gait analysis (rehabilitation, neurology department):rn7. Kinematics research (sports school). Software introduction rnsoftware modules mainly include case registration, case management, surface emg test item, testing item, surface emg training items, upload dynamically, data conversion, gain calibration, system setup, help and exit.
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
product descriptionbio-feedback electrotherapy system uses certain intensity of the low-frequency pulses, through a pre-set program to stimulate nerve or muscle, to make muscle tense or relax, which can achieve some kinds of movement of paralyzed muscles and improve or restore muscle functions. Feedback stimulation can show real-time muscle rms waveform histogram and make feedback stimulation therapy by setting thresholds. Combined with specialized pelvic floor assessment methods, template training methods, multi-media biofeedback training and other therapy programs, it can choose different therapy programs according to different stage of therapy. main features 1. Flexible working modes: neuromuscular electrical, emg triggered stimulation, tens, pelvic floor evaluation and training. Surface emg evaluation and multimedia biofeedback, template training.2. Restore nerve and muscle connection, relieve muscle spam, and promote muscle function recovery; combine active and passive stimulation to re-control paralyzed muscles;3. Make use of state-of-the-art surface emg acquisition and analysis technology, get sensitive, accurate and real-time feedback and assist make appropriate assessment and treatment plan;4. Pelvic floor treatment: help patients to recover early the pelvic floor neuromuscular function;5. Convenient, multiple and visual training templates; simple, funny and personalized game training make treatment no longer boring;rnworking modesrn1. Stimulationrnprescription stimulationrnfree stimulationrnfeedback stimulationrntensrn2. Multi-media traininrnrelax trainingrnreinforce trainingrnsynergy trainingrnaccuracy trainingrnendurance trainingrn3. Template trainingrntotal 17 training templatesrn4 surface emgrnevaluation & diagnosisrn5 pelvic floor evaluation
brief description:rnbio-feedback electrotherapy systemrnneuromuscular electrical, emg triggered stimulation, tensrnpelvic floor evaluation and trainingrnsurface emg evaluationrnmultimedia biofeedback and template trainingrndescription of bio-feedback electrotherapy systembio-feedback electrotherapy system (model myopfr) use certain intensity of the low-frequency pulses, through a pre-set program to stimulate nerve or muscle, to make muscle tense or relax, which can achieve some kinds of movement of paralyzed muscles and improve or restore muscle functions. Feedback stimulation can show real-time muscle rms waveform histogram and make feedback stimulation therapy by setting thresholds. Combined with specialized pelvic floor assessment methods, template training methods, multi-media biofeedback training and other therapy programs, it can choose different therapy programs according to different stage of therapy.Rnmain featuresrn1.flexible working modes: neuromuscular electrical, emg triggered stimulation, tens, pelvic floor evaluation and training. Surface emg evaluation and multimedia biofeedback, template training.rn2.restore nerve and muscle connection, relieve muscle spam, and promote muscle function recovery; combine active and passive stimulations to re-control paralyzed muscles;rn3.make use of state-of-the-art surface emg acquisition and analysis technology, get sensitive, accurate and real-time feedback and assist make appropriate assessment and treatment plan;rn4.pelvic floor treatment: help patients to recover early the pelvic floor neuromuscular function;rn5.convenient, multiple and visual training templates; simple, funny and personalized game training make treatment no longer boring;rn6.optional central monitoring program: perfect case management, real-time wireless data transmission, and save data in sd card easily.
to reduce the risk of nerve damage during surgery by monitoring trigger emg activity:rn1. Monitoring trigger emg during surgery;rn2. Various prompts for different emg trigger setting;rn3. To save & replay of electrophysiological waveforms in real time;rn4.to locate nerve and distinguish some special nerve during surgery. Specification:rn1. Hardwarernamplifier channel: 4 channel, 8 channel;rnstimulation current: 0-30ma, stimulation frequency: 1-30hz;rnpulse width:50s, 100s, 150s, 200s, 250s;rnsound & voice prompt for event;rnelectric knife / coagulation available for monitoring with event mark in silence;rnelectrode -off alarming periodically or in a real time;rn2. Monitoring itemrntrigger emg: identify the tissue function and judge nerve;rn3. Alarming or promptrnclinic alarming: alarming (including sound, dialog box and event marking) would come with the physiologic wave reaching the limit;rnprompt: base on the setting, it would make the prompt as reaching the limit, rnsuch as when the electric knife / coagulation is working or when the nervernstimulation make the muscle movement;rntechnique alarming: equipment failure, such as communication or powerrnfailure waveform recording.rn4. Surgery recording:rnwaveform recording: recording typical waveform in different stage ofrnsurgery and the emg response trend;rnevent recording: recording various kind of emg waveform when it reach thernthreshold value set;rn5. Easy software operation:rnwave track: recording typical waveform in different stage of surgery and thernemg response trend;rnevent recording: recording various kind of emg waveform when it reach thernthreshold value.
examination protocols:
electromyography (emg):
motor unit potential (mup)
interference phase (ip)
scanning emg
evoked potential (ep):
somatosensory evoked potential (sep):
usep; lesep; tsep; scep
acoustic evoked potential (aep)
baep, maep, laep, ecochg (electro-oculogram), 40hz
visual evoked potential (vep)
prvep, fvep, erg, eog
nerve conductive studies (ncv)
motor ncv (mcv)
sensory ncv (scv)
short segment conduction (ssct)
repetitive nerve stimulation (rns)
f-wave
h-reflex
blink reflex (br)
sympathetic skin response (ssr)
.main features of 7128w-d36-ep 36 channel eegpsgerprnprofessional eeg amplifier suitable for all standard applications of routine eeg and long term eeg monitoring in the research and clinical areas. configurable in a number of setups according to users needsrn24 channels monopolar eeg;rn12 channels monopolar eeg + 12 channels bipolar eeg;rn24 channels monopolar eeg + 12 channels polysomnography (psg) parameters (including ecg (1 channel with 2 leads), airflow (1 channel), eog (2 channels), emg (3 channels), snore (1 channel), spo2 (1 channel), thoracic abdominal breathing (2 channels), body position (1 channel)) + erp examination. 24 bits ad conversion rate, with high sampling rate of up to 8 khz. high quality real-time eeg signal acquisition is transmitted via fiber optical isolation, which shields away interference from power line and other signals, transmitting stable and reliable measurement data at high-speed while greatly ensuring patients safety. amplifier can be operated either by dc power without affecting signal quality. head-box design to access single shielded cupclip electrodes with touch proof connectors (1.5mm). built-in impedance testing function and automatic calibration (for both sine wave and square wave signals). optional video system for recording, editing and displaying video images synchronously with eeg signals. Delivery time 3-5 days after payment confirmed package 1 carton
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
20 channel ambulatory eeg wireless bluetooth channel: 19 ch eeg + 1 ch ecg; 1. Event button to mark patient's epilepsy seizure; 2. Plug and play single electrode (din interface). Supports 19 eeg channels plus 1 channel ecg to meet with doctor's clinical requirements; low power consumption, capable of supporting up to 72 hours recording with 4 aa batteries; use of dc power supply eliminates risk of electric shock to patients and prevents signal interference, and removes the need to use ground wire or other shielding features; supports real-time eeg waveform recording and display via wireless bluetooth transmission, or dynamic recording with flash memory card capable of storing up to 2gb of eeg data (data storage capability depends fully on memory card used); fast data uploading capability: data stored in flash memory card via dynamic recording can be quickly transmitted to desktop or laptop computer through usb 2.0usb1.1 interface; single electrodes with touch proof connectors that meets international standard, and can be replaced individually if necessary; event button on the amplifier enables on-the-spot manual event marking of patient's epilepsy seizure during recording; compact design and easy to carry, complete with eeg signal isolation to support maximum patient movement without distortion; optional video system for recording, editing and displaying video images synchronously with eeg signals. Package: 1 carton delivery time: 3-5 days after payment confirmed
this is a professional digital eeg device designed and developed to allow cliniciansrnto perform all standard applications of routine eeg and long term eeg monitoring anywhere due to its portable and compact design. Rnit also has low power consumption making it capable of supporting up to 72 hours recording with just four aa batteries. Rnthis device supports real-time eeg waveform recording and display via wi-fi and dynamic recording with flash memory card. Rnkey featurern rn1.compact design portable and easy to carry. Rn2.complete with eeg isolation support maximum patient movement without distortion. Rn3.user-friendly operation. Rn4.low power consumption capable of supporting up to 72 hours recording with fourrnaa rnbatteries. Rn5.supports real-time eeg waveform recording, display via wi-fi. Rn6.dynamic recording with flash memory card. Rn7.all-in-one electrode cable for easy connection. Rn8.use of dc power supply: eliminates risk of electric shock to patientsrn prevents signal interferencern removes the need to use ground wire or other shielding featuresrn rn9.fast data uploading capability stored data in flash memory card can be quickly transferred to the computer through usb2.0/usb 1.1 interface. Rn10.optional video system recording, editing and displaying of video synchronously with eeg signals.
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
The new NS-SOMNORMAL-3 is a compact and portable device which can be connected to an Android or iOS mobile device to access the mobile application for treatment of Insomnia allowing users to use the device wherever they go. This device uses Cranial Electrotherapy Stimulation (CES), which is a form of a non-invasive brain stimulation that applies a small, pulsed electric current across a person’s head to treat insomnia through electrodes placed on the ear lobes.
Clinical Application :
Application Department :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Technical Specifications
Hardware | |||
---|---|---|---|
Size Dimensions | 187 x 113 X 48 mm | ||
Power Supply | Charge with USB | ||
Operation Duration | >=140 mins stimulation | ||
Current Intensity | 0-600uA | ||
Current Setting Resolution | 50uA | ||
Stimulation Frequency | 0.5 Hz | 1.5 Hz | 100 Hz |
Stimulation Time | 0-20 minutes | ||
Load Impedance | 100Ω ~ 15K |
The new NS-EEG-D1-W is a professional digital AEEG device available in 16/24/32/64 channels. This device has a compact design making it portable and can be easily carried while also having low power consumption making it capable of supporting up to 72 hours recording with four AA batteries. This device is suitable for all standard applications of routine EEG and long-term EEG monitoring. Supports real-time EEG waveform recording and display via Wi-Fi and dynamic recording with Flash memory card.
Integrated Functions :
Displays :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Technical Specifications
Dimensions & Weights | |
---|---|
Size | 130 x 89 X 40 mm |
Amplifier Weight | 250 g (approx) |
Power Supply | |
Power | 4 – AA batteries |
Operation Time | |
Duration | Up to 72 hours |
Performance | |
Input Impedance | ≥ 1000MΩ |
Noise level | <0.4μV (rms) |
CMRR | ≥ 110dB |
Resistance polarization voltage | ± 300mV |
Frequency characteristics | 0.5Hz ~ 10KHz, error of +5% ~ -30% |
Channel Configuration | 16/24/32/64 channel EEG, where 8 channels can custom functionality: EEG. ECG. Eye movement, etc. |
Sampling Frequency | 128Hz, 256Hz, 512Hz, 1KHz, 2KHz, 4KHz, 8KHz |
Precision Sampling Resolution | 16/24bit |
Digital Low-pass Filter Control | 15Hz, 30Hz, 40Hz, 60Hz, 120Hz, 250Hz, 1KHz, 3KHz, etc. |
Digital Time Constant Control | 0.01s, 0.02s, 0.03s, 0.1s, 0.2s, 0.3s, 1s, 2s, 3s, etc. |
Amplification | 1 – 10,000 times |
Neuro Rehabilitation device including accessment, game play and training, stimulations. This system consists of electric stimulation and SEMG, and is mainly used for muscles and nerve training.
There are 4 modules in this device:
System Key Features :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Technical Parameter
Dimensions | |
---|---|
Size | 172 x 30 x 52mm |
Weight | 0.505kg (without batteries) |
Display | 9-inch colored touch-screen LCD |
Power Supply | |
Power | DC 12V/1.5A |
Performance | |
Stimulation Frequency | 1 – 120 Hz |
Stimulation Intensity | up to 100mA |
Stimulation Pulse Width | 50 – 500μs |
CMRR | ≥100dB |
Short Circuit Noise | ≤0.5μV (RMS) |
key featuresrnsupport both iso & android systemrnpocket-size design & simple operationrnshort treatment period & no side effectrnbluetooth connection to smart phonernprofessional assessment of insomnia, anxiety and depressionrnassessment & treatment data can be saved to cloud rnclinical applicationrnsomnormal can be used for treatment of insomnia, anxiety and depression. Delivery time: 3-5 days after payment confirmed package: 1 carton
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
featuresrn1. Multi-channel acquisition: optional 8 and 16 channels with high anti-interference capacity; rn2. Real-time wireless data transmission, dynamic data storage suitable for signal acquisition in movement state; rn3. Multiple data processing and analysis reports: standard, fatigue, coordination, average activity, power spectrum, symmetry etc., exportable for further analysis; rn4. Multi-media biofeedback games make training more efficient and no longer boring. rn5. Non-invasive: no need to insert needle into the detected muscle, and just stick electrodes on the surface of detected musclern rn6. Multiple quantitative assessment: occurrence period, amplitude, rms value and frequency of emg activity potential and all kinds of analysis reports. rn7. Program modules function: 6 types semg test and reports for different situation, funny semg biofeedback game training; rn8. Human-friendly software: acquisition, display, analysis and reports generating. Rnapplicationsrnthis equipment can be widely used in hospitals, sports science and lab research. 1. Hemiplegia assessment after cerebral palsy and stroke (neurology, rehabilitation department)rn2. Pain assessment, balance function evaluation, neuromuscular disease diagnosisrn3. Scoliosis, torticollis generic program (pediatrics, rehabilitation department):rn4. Feedback muscle training, muscle function/movement evaluation (rehabilitation department):rn5. Fatigue research (rehabilitation department, sports schools, and athletic teams);rn6. Gait analysis (rehabilitation, neurology department):rn7. Kinematics research (sports school). software introduction rnsoftware modules mainly include case registration, case management, surface emg test item, testing item, surface emg training items, upload dynamically, data conversion, gain calibration, system setup, help and exit.
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
key featuresrnsupport both iso & android systemrnpocket-size design & simple operationrnshort treatment period & no side effectrnbluetooth connection to smart phonernprofessional assessment of insomnia, anxiety and depressionrnassessment & treatment data can be saved to cloud rnclinical applicationrnsomnormal can be used for treatment of insomnia, anxiety and depression. Delivery time: 3-5 days after payment confirmed package: 1 carton
Additional Information:
Payment Terms : L/C, T/T, Western Union,
Packaging Details : Shipping cost depends on client's preferred courier.
Package weight and size depends on components preferred by client.
Delivery Time : 3-5 Days after payment confirmed
The NS-SIOM-1E is a touch-screen, user-friendly intraoperative monitoring system available in 4 or 8 channels, which has wide applications for use during different types of surgery. This device helps reduce the risk of nerve damage during surgery and identify nerve functions before the end of surgery through monitoring of triggered EMG activities in multiple cranial and peripheral nerves. NS-SIOM-1E is applicable for Facial Nerve, Thyroid, Spinal, ENT and other general surgeries.
Hardware Components :
Additional Information:
Packaging Details : Carefully packaged to avoid damage
Technical Specifications
Hardware | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Amplifier Channels | 8 channels | |||||||||||||||||
Stimulation Current | 0-30mA | |||||||||||||||||
Stimulation Frequency | 1-30Hz | |||||||||||||||||
Pulse Width | 20μs | 50μs | 100μs | 150μs | 200μs | 250μs | ||||||||||||
Event Prompt (Sound & Voice) | Electric Knife/Coagulation mute function during monitoring Electrode-off Periodical Alarm (Real-time) | |||||||||||||||||
Feedback Display & Notification | Visual display and Audio feedback | |||||||||||||||||
Other Features | Default and Customizable procedure setting Data saving and reporting Electrode status checking | |||||||||||||||||
Evoked EMG (Acquisition) | ||||||||||||||||||
Scanning Speed | 0.1 ms/D | 0.5 ms/D | 2 ms/D | 5 ms/D | ||||||||||||||
10 ms/D | 20 ms/D | 100 ms/D | 200 ms/D | |||||||||||||||
Sensitivity | 5 uv/D | 10 uv/D | 20 uv/D | 50 uv/D | ||||||||||||||
100 uv/D | 200 uv/D | 500 uv/D | 1,000 uv/D | |||||||||||||||
2,000 uv/D | 5,000 uv/D | 10,000 uv/D | 20,000 uv/D | |||||||||||||||
Free Scanning EMG (Acquisition) | ||||||||||||||||||
Scanning Speed | 0.1 ms/D | 0.5 ms/D | 2 ms/D | |||||||||||||||
5 ms/D | 10 ms/D | 20 ms/D | ||||||||||||||||
Sensitivity | 5 uv/D | 10 uv/D | 20 uv/D | 50 uv/D | 100 uv/D | |||||||||||||
200 uv/D | 500 uv/D | 1,000 uv/D | 2,000 uv/D | 5,000 uv/D | ||||||||||||||
10,000 uv/D | 20,000 uv/D | 50,000 uv/D | ||||||||||||||||
Stimulation Frequency | 1-30Hz | |||||||||||||||||
Pulse Width | 50μs | 100μs | 150μs | 200μs | 250μs | |||||||||||||
Low-cut | 0.1 | 0.2 | 0.3 | 0.5 | ||||||||||||||
1 Hz | 2 Hz | 3 Hz | 5 Hz | |||||||||||||||
10 Hz | 20 Hz | 30 Hz | 50 Hz | |||||||||||||||
100 Hz | 200 Hz | 300 Hz | 500 Hz | |||||||||||||||
High-cut | 10 Hz | 20 Hz | 30 Hz | 50 Hz | 100 Hz | |||||||||||||
200 Hz | 300 Hz | 500 Hz | 1 KHz | 2 KHz | ||||||||||||||
3 KHz | 5 KHz | 10 KHz | ||||||||||||||||
Magnification | 45 or 1,800 multiple | |||||||||||||||||
Notch Waveform | Up to 50Hz or 60Hz can be set |